Air shower

Air shower

Introdution

Air shower room is also called wind shower room, clean air shower room, clean air shower room, air shower room, air shower room, air shower door, bath dust room, shower room, air shower passage, air shower room.

The air shower room is a necessary passage to enter the clean room, which can reduce the pollution problem caused by entering and leaving the clean room.

The air shower room is a kind of local purification equipment with strong universality, which is installed between clean room and unclean room.

When people and goods want to enter the clean area, they need to go through the air shower room. The clean air can remove the dust carried by people and goods, and effectively block or reduce the dust source to enter the clean area.

The front and rear doors of the air shower room/shower room are interlocked electronically and act as air lock to prevent unpurified air from entering the clean area.


Use of the Air shower


1, open stainless steel air shower door after entering the air shower, air shower door immediately automatically shut down the outside door, infrared ray (acoustic/human heat) induction, air shower automatic start blowing for 15 seconds (the factory has been set).

Note: two stainless steel doors cannot be opened at the same time when the air shower chamber is spraying. If forced opening will damage the electronic lock, the two doors of the air shower chamber are electronic interlock control.

2. After the end of spraying, push the door open and enter the clean room.


Fault treatment


1. When the air shower chamber is used for a period of time, if the wind speed is very low, it shall immediately check whether the filter in the air shower chamber accumulate too much dust. If it is, it shall be replaced.

It is usually necessary to exchange once every 1-6 months, and efficient filters are usually exchanged once every 6-12 months.

2. Check the light sensing system at the lower right corner of the box in the shower room to see if the light sensing device is correct if there is no automatic induction of water spraying in the shower room.

If the emergency stop button is red color, it means that the drench room will not be drench, only need to press the emergency stop button ,it can be normal operation.

3. When the air shower room is not working, the first thing to check is whether the urgent switch of air shower outside the door can be blocked. If it is blocked, quietly press it with your hand and rotate it to the right .

4.It is necessary to check whether the 380V three-phase four wire can be connected backwards if  the wind speed in the shower room is very low. If the wire source of the drench room is connected backwards, it may cause the drench room fan to not operate or the wind speed of the drench room to decrease, or it will burn the circuit board of the whole drench room.


Nine maintenance


1. Regularly use the instrument to measure various technical indicators of the equipment, and if it does not meet the requirements of technical parameters, it shall be timely handled.

2. Remove the filter material from the primary effect air filter regularly according to the actual use situation.

3, when wind speed change hours should be at the beginning of the first check air filter surface is black, if black shows the pre-filter let dust is more, resistance increases, which should be removed in the early of the non-woven fabric air filter and clean or change.

4. When the non-woven fabric is replaced or cleaned, but the wind speed still cannot be increased, it indicates that the high-efficiency air filter has been blocked, causing increased resistance, then the high-efficiency air filter should be replaced.

5. When replacing the high-efficiency filter, the ball spraying plate shall be removed, the high-efficiency filter shall be taken out, and the new high-efficiency air filter shall be replaced according to the specifications and models of the original high-efficiency filter.

The arrow mark on the high efficiency filter should be confirmed when installing. The arrow should point in the direction of airflow.

And make sure the seal is good to prevent leakage.

6. After the replacement of the high-efficiency filter, the border shall be confirmed free of leakage and the dust particle counter shall be used for detection. The technical indicators shall be met before the normal operation can be carried out.

7. Conduct regular maintenance of electrical lines. If there is any fault, please refer to the electrical schematic diagram for maintenance.

8.Maintain the door regularly so that the electronic lock is aligned with its lock hole, so as to avoid the lock pin sticking.

9, this equipment use temperature shall not exceed 50 , and open flame is strictly prohibited.



Service phone: